Proceedings of the American Thoracic Society Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Related articles in Proceedings of the American Thoracic Society
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kohl, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kohl, G.
The Proceedings of the American Thoracic Society 2:470-476 (2005)
© 2005 The American Thoracic Society

The Evolution and State-of-the-Art Principles of Multislice Computed Tomography

Gerhard Kohl

Siemens Medical Solutions, Computed Tomography, Forchheim, Germany

Correspondence and requests for reprints should be addressed to Gerhard Kohl, M.S., Siemens Medical Solutions, CT, 1 Siemens Street, Forchheim 91301, Germany. E-mail: gerhard.kohl{at}siemens.com

ABSTRACT

Computed tomography has revolutionized diagnostic radiology with the introduction of spiral CT in the early 1990s, allowing for the first time the acquisition of volume data without the danger of misregistration or double registration of anatomical details. The next revolution occurred in 1998 when all major CT manufacturers introduced multislice CT (MSCT) systems, which typically offered simultaneous acquisition of four slices, providing considerable improvement towards the goal of isotropic three-dimensional imaging. The most recent generation of MSCT systems acquire 64 slices per rotation, enabling a whole body CTA with 1,500 mm scan range and an isotropic resolution of down to 0.4 mm in only 22– 25 s. The tube and the detector measurement system belong to the most important system components of a CT system, having a large influence on system performance. For example, new rotating envelope tube design principles allow for faster rotation times and for double z-sampling techniques in order to increase resolution. The applied dose is ultimately the limiting factor for the improvement of image quality and increase in isotropic resolution. In order to make best diagnostic use of the applied dose, sophisticated dynamic dose adaptation techniques to patient size and geometry have been developed.

Key Words: computed tomography design • computed tomography principles • multislice computed tomography • spiral computed tomography